Login
Apna shehar auto detect karein?

Growatt inverter error codes: poori list aur matlab

Growatt ke do qisam ke inverter aam hain. Off-grid ya hybrid SPF inverter (battery wale) do hindson ka code dikhate hain, jaise 04 ya 09. On-grid MIN ya MIC inverter (bina battery) teen hindson ka code dikhate hain, jaise 302. Apni screen ke hisaab se neeche sahi table dekhein.

Update: 11-Nov-2026

Yeh codes Growatt SPF series (jaise SPF 3500/5000 ES, SPF 6000 ES Plus, SPF 3000TL HVM) aur MIN TL-X on-grid series ki manuals se hain. Doosri series mein ek hi number ka matlab alag ho sakta hai, is liye apne inverter ka model zaroor dekhein.

Koi bhi code aaye to pehle yeh karein

  • Screen par code, aur yeh ke "Warning" hai ya "Fault/Error", likh lein. Laal light jalti bujhti ho to aksar warning hai, lagataar jale to fault.
  • Bhaari cheezein band kar ke load kam karein.
  • Inverter band karein, 5 minute ruk kar dobara on karein.
  • Inverter ke aas paas hawa ka rasta khula rakhein.

Hifazat: bijli ke panel, board, gas pipe ya inverter ke andar khud haath na dalein. Is se karant lag sakta hai ya gas nikal sakti hai. Yeh kaam mistri ka hai.

Off-grid / hybrid (SPF series, battery wale)

01 se 09 aur 51 se 62 fault codes hain. 10, 12, 13, 14, 19, 20 aur 21 warning hain. 01, 02, 03, 04 aur 07 warning bhi ho sakte hain aur fault bhi.

CodeMatlab
01Inverter ka pankha (fan) ruka hua ya kharab.
02Inverter ke andar temperature had se zyada (over temperature). Tafseel
03Battery ka voltage had se zyada (battery over-charge). Tafseel
04Battery ka voltage kam (low battery). Warning mein beep, fault mein inverter band. Tafseel
05Output par short circuit. Tafseel
06Output voltage had se zyada.
07Overload: load inverter ki taqat se zyada, waqt poora hone par band. Tafseel
08Andar ka DC (bus) voltage had se zyada. Tafseel
09Bus soft start fail: inverter andar se start nahi ho saka. Tafseel
10Warning: inverter ne output power kam kar di (derating), aksar garmi ki wajah se.
12Warning: battery kam hone ki wajah se solar charging ruk gayi.
13Warning: panels ka voltage zyada hone se solar charging ruk gayi.
14Warning: overload ki wajah se solar charging ruk gayi.
19Warning: battery juri hui nahi (battery disconnect). Tafseel
20Warning: lithium battery inverter se baat nahi kar rahi (BMS communication).
21Warning: panels se bijli kaafi nahi (PV power insufficient).
51Zyada current ya jhatka (over current / surge).
52Andar ka DC (bus) voltage had se kam.
53Inverter soft start fail (andar ke part ki kharabi).
56Battery ka connection khula hai ya fuse jal gaya.
57Current sensor kharab (andar ke part ki kharabi).
58Output voltage had se kam.
60Negative power fault: aksar parallel inverters ki wiring ya setting ka masla.
61Panels ka voltage had se zyada.
62Inverter ke andar communication ki kharabi.

On-grid (MIN / MIC TL-X series, bina battery)

Screen par "Error" ya "Warning" ke saath number aata hai. 200 aur 300 wale zyada tar ghar, panel ya grid ke masle hain; 400 wale zyada tar inverter ke andar ke.

CodeMatlab
200AFCI fault: DC taaron mein chingari (arc) pakri gayi.
201Leakage current zyada (current zameen ki taraf ja raha hai).
202Panels ka DC voltage had se zyada.
203PV isolation low: panel ya DC taaron ka insulation kamzor (aksar nami). Tafseel
300Grid (WAPDA) ka voltage ijazat wali had se bahar. Tafseel
302No AC connection: inverter ko grid ki bijli nahi mil rahi. Tafseel
303PE abnormal: neutral aur earth ke darmiyan voltage zyada (earthing ka masla).
304Grid ki frequency ijazat wali had se bahar.
402Output mein DC current zyada (output high DCI).
404Error 404: bus voltage ki sampling kharab (andar ka masla). Warning 404 ka matlab memory (EEPROM) ki kharabi hai.
405Error 405: relay fault. Warning 405 ka matlab firmware version ka farq hai. Tafseel
407Auto test fail: inverter ka apna self test paas nahi hua.
408Inverter ka temperature had se zyada (over temperature).
409Andar ka DC (bus) voltage had se zyada (bus over voltage). Tafseel
411Inverter ke andar do boards (DSP aur M3) ka rabta kharab.
414Memory chip (EEPROM) ki kharabi.
420GFCI fault: zameen ki taraf current leak ki hifazati circuit ki kharabi.
401Warning: inverter aur meter ka rabta kharab.

Aam sawal

Growatt inverter ka error kaise reset karein?

Load kam karein, inverter band karein aur 5 minute baad on karein. Warning wale codes wajah door hone par khud chale jate hain. Fault wala code restart ke baad bhi rahe to inverter ya wiring mein kharabi hai aur solar mistri ko dikhana chahiye.

Kya main inverter khud khol kar theek kar sakta hoon?

Inverter ke andar solar panel aur battery ka DC current hota hai jo bijli band karne ke baad bhi jaan le sakta hai. Inverter ka cover ya DC taarein khud kabhi na kholein.

Code nahi gaya?

Apne shehar ka checked mistri bulayein

Form bharein aur ilaqe ka mistri aap ko call karega. Code ka number bhi likh dein taa ke woh sahi part le kar aaye.

Mistri bulayein

Aap mistri hain? Apna free page banayein: ilaqe ke grahak seedha aap ko call karein

Register karna free hai. Kaam ke paise par koi commission nahi.

Free page banayein