Growatt inverter error codes: poori list aur matlab
Growatt ke do qisam ke inverter aam hain. Off-grid ya hybrid SPF inverter (battery wale) do hindson ka code dikhate hain, jaise 04 ya 09. On-grid MIN ya MIC inverter (bina battery) teen hindson ka code dikhate hain, jaise 302. Apni screen ke hisaab se neeche sahi table dekhein.
Update: 11-Nov-2026
Yeh codes Growatt SPF series (jaise SPF 3500/5000 ES, SPF 6000 ES Plus, SPF 3000TL HVM) aur MIN TL-X on-grid series ki manuals se hain. Doosri series mein ek hi number ka matlab alag ho sakta hai, is liye apne inverter ka model zaroor dekhein.
Koi bhi code aaye to pehle yeh karein
- Screen par code, aur yeh ke "Warning" hai ya "Fault/Error", likh lein. Laal light jalti bujhti ho to aksar warning hai, lagataar jale to fault.
- Bhaari cheezein band kar ke load kam karein.
- Inverter band karein, 5 minute ruk kar dobara on karein.
- Inverter ke aas paas hawa ka rasta khula rakhein.
Hifazat: bijli ke panel, board, gas pipe ya inverter ke andar khud haath na dalein. Is se karant lag sakta hai ya gas nikal sakti hai. Yeh kaam mistri ka hai.
Off-grid / hybrid (SPF series, battery wale)
01 se 09 aur 51 se 62 fault codes hain. 10, 12, 13, 14, 19, 20 aur 21 warning hain. 01, 02, 03, 04 aur 07 warning bhi ho sakte hain aur fault bhi.
| Code | Matlab |
|---|---|
| 01 | Inverter ka pankha (fan) ruka hua ya kharab. |
| 02 | Inverter ke andar temperature had se zyada (over temperature). Tafseel |
| 03 | Battery ka voltage had se zyada (battery over-charge). Tafseel |
| 04 | Battery ka voltage kam (low battery). Warning mein beep, fault mein inverter band. Tafseel |
| 05 | Output par short circuit. Tafseel |
| 06 | Output voltage had se zyada. |
| 07 | Overload: load inverter ki taqat se zyada, waqt poora hone par band. Tafseel |
| 08 | Andar ka DC (bus) voltage had se zyada. Tafseel |
| 09 | Bus soft start fail: inverter andar se start nahi ho saka. Tafseel |
| 10 | Warning: inverter ne output power kam kar di (derating), aksar garmi ki wajah se. |
| 12 | Warning: battery kam hone ki wajah se solar charging ruk gayi. |
| 13 | Warning: panels ka voltage zyada hone se solar charging ruk gayi. |
| 14 | Warning: overload ki wajah se solar charging ruk gayi. |
| 19 | Warning: battery juri hui nahi (battery disconnect). Tafseel |
| 20 | Warning: lithium battery inverter se baat nahi kar rahi (BMS communication). |
| 21 | Warning: panels se bijli kaafi nahi (PV power insufficient). |
| 51 | Zyada current ya jhatka (over current / surge). |
| 52 | Andar ka DC (bus) voltage had se kam. |
| 53 | Inverter soft start fail (andar ke part ki kharabi). |
| 56 | Battery ka connection khula hai ya fuse jal gaya. |
| 57 | Current sensor kharab (andar ke part ki kharabi). |
| 58 | Output voltage had se kam. |
| 60 | Negative power fault: aksar parallel inverters ki wiring ya setting ka masla. |
| 61 | Panels ka voltage had se zyada. |
| 62 | Inverter ke andar communication ki kharabi. |
On-grid (MIN / MIC TL-X series, bina battery)
Screen par "Error" ya "Warning" ke saath number aata hai. 200 aur 300 wale zyada tar ghar, panel ya grid ke masle hain; 400 wale zyada tar inverter ke andar ke.
| Code | Matlab |
|---|---|
| 200 | AFCI fault: DC taaron mein chingari (arc) pakri gayi. |
| 201 | Leakage current zyada (current zameen ki taraf ja raha hai). |
| 202 | Panels ka DC voltage had se zyada. |
| 203 | PV isolation low: panel ya DC taaron ka insulation kamzor (aksar nami). Tafseel |
| 300 | Grid (WAPDA) ka voltage ijazat wali had se bahar. Tafseel |
| 302 | No AC connection: inverter ko grid ki bijli nahi mil rahi. Tafseel |
| 303 | PE abnormal: neutral aur earth ke darmiyan voltage zyada (earthing ka masla). |
| 304 | Grid ki frequency ijazat wali had se bahar. |
| 402 | Output mein DC current zyada (output high DCI). |
| 404 | Error 404: bus voltage ki sampling kharab (andar ka masla). Warning 404 ka matlab memory (EEPROM) ki kharabi hai. |
| 405 | Error 405: relay fault. Warning 405 ka matlab firmware version ka farq hai. Tafseel |
| 407 | Auto test fail: inverter ka apna self test paas nahi hua. |
| 408 | Inverter ka temperature had se zyada (over temperature). |
| 409 | Andar ka DC (bus) voltage had se zyada (bus over voltage). Tafseel |
| 411 | Inverter ke andar do boards (DSP aur M3) ka rabta kharab. |
| 414 | Memory chip (EEPROM) ki kharabi. |
| 420 | GFCI fault: zameen ki taraf current leak ki hifazati circuit ki kharabi. |
| 401 | Warning: inverter aur meter ka rabta kharab. |
Aam sawal
Growatt inverter ka error kaise reset karein?
Load kam karein, inverter band karein aur 5 minute baad on karein. Warning wale codes wajah door hone par khud chale jate hain. Fault wala code restart ke baad bhi rahe to inverter ya wiring mein kharabi hai aur solar mistri ko dikhana chahiye.
Kya main inverter khud khol kar theek kar sakta hoon?
Inverter ke andar solar panel aur battery ka DC current hota hai jo bijli band karne ke baad bhi jaan le sakta hai. Inverter ka cover ya DC taarein khud kabhi na kholein.