Growatt inverter error codes: full list and meanings

Two kinds of Growatt inverter are common. Off-grid or hybrid SPF inverters (with battery) show two-digit codes, such as 04 or 09. On-grid MIN or MIC inverters (no battery) show three-digit codes, such as 302. Use the table below that matches your screen.

Updated 11-Nov-2026

These codes come from the manuals of the Growatt SPF series (such as SPF 3500/5000 ES, SPF 6000 ES Plus, SPF 3000TL HVM) and the MIN TL-X on-grid series. Other series can use the same number for something else, so check your inverter's model.

For any code, try this first

  • Write down the code, and whether the screen says "Warning" or "Fault/Error". A flashing red light is usually a warning; a steady one is a fault.
  • Switch off heavy appliances to reduce the load.
  • Switch the inverter off, wait 5 minutes and switch it on again.
  • Keep the airflow around the inverter clear.

Safety: never reach into an electrical panel, board, gas pipe or the inside of an inverter yourself. You can get a shock or release gas. This is a mistri's job.

Off-grid / hybrid (SPF series, with battery)

01 to 09 and 51 to 62 are fault codes. 10, 12, 13, 14, 19, 20 and 21 are warnings. 01, 02, 03, 04 and 07 can show as a warning or a fault.

CodeMeaning
01Inverter fan is locked or faulty.
02Over temperature inside the inverter. Details
03Battery voltage too high (over-charged). Details
04Battery voltage low. As a warning it beeps; as a fault the inverter stops. Details
05Output short circuit. Details
06Output voltage too high.
07Overload: load above the inverter's rating for too long. Details
08Internal DC bus voltage too high. Details
09Bus soft start failed: the inverter could not start internally. Details
10Warning: output power derating, often because of heat.
12Warning: solar charger stopped because the battery is low.
13Warning: solar charger stopped because PV voltage is too high.
14Warning: solar charger stopped because of overload.
19Warning: battery disconnected. Details
20Warning: lithium battery not communicating with the inverter (BMS).
21Warning: not enough power from the panels.
51Over current or surge.
52Internal DC bus voltage too low.
53Inverter soft start failed (internal fault).
56Battery connection open or fuse blown.
57Current sensor failed (internal fault).
58Output voltage too low.
60Negative power fault: usually parallel-inverter wiring or settings.
61PV (panel) voltage too high.
62Internal communication error.

On-grid (MIN / MIC TL-X series, no battery)

The screen shows "Error" or "Warning" with the number. 200 and 300 codes are mostly about the house, panels or grid; 400 codes are mostly inside the inverter.

CodeMeaning
200AFCI fault: an arc was detected on the DC side.
201Residual (leakage) current too high.
202PV DC input voltage above the maximum.
203PV isolation low: weak insulation on panels or DC wires (often moisture). Details
300Grid voltage out of the permitted range. Details
302No AC connection: the inverter cannot see grid power. Details
303PE abnormal: voltage between neutral and earth too high (earthing problem).
304Grid frequency out of the permitted range.
402Output DC current component too high (high DCI).
404Error 404: bus voltage sampling fault (internal). Warning 404 means a memory (EEPROM) fault.
405Error 405: relay fault. Warning 405 means a firmware version mismatch. Details
407Auto test failed: the inverter's self-test did not pass.
408Inverter over temperature.
409Internal DC bus over voltage. Details
411Communication fault between the inverter's internal boards (DSP and M3).
414EEPROM (memory chip) fault.
420GFCI fault: fault in the earth-leakage protection circuit.
401Warning: inverter cannot communicate with the meter.

Common questions

How do I reset a Growatt inverter error?

Reduce the load, switch the inverter off and switch it on after 5 minutes. Warning codes clear by themselves once the cause is gone. If a fault code stays after a restart, the inverter or wiring has a fault and a solar mistri should look at it.

Can I open the inverter and fix it myself?

An inverter carries DC current from the panels and battery that can kill, even after the mains is off. Never open the inverter cover or the DC wires yourself.